空间无缝光谱仪光谱效率测试及误差分析
作者:
作者单位:

1. 中国科学院南京天文光学技术研究所 南京 210042;2. 中国科学院天文光学技术重点实验室(南京天文光学技术研究所) 南京 210042;3. 中国科学院大学南京学院 南京 211135

作者简介:

通讯作者:

中图分类号:

基金项目:

国家自然科学基金项目(12273081、12173061)资助


Spectral Efficiency Testing and Error Analysis of Space Slitless Spectrograph
Author:
Affiliation:

1. Nanjing Institute of Astronomical Optics & Technology, Chinese Academy of Sciences, Nanjing 210042;2. CAS Key Laboratory of Astronomical Optics & Technology, Nanjing Institute of Astronomical Optics & Technology, Nanjing 210042;3. University of Chinese Academy of Sciences, Nanjing 211135;

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    中国空间站巡天望远镜(Chinese Space Survey Telescope, CSST)无缝光谱组件将安装在巡天模块主焦面探测器前面, 用于开展大视场、宽波段的无缝光谱观测. 无缝光谱组件作为巡天模块的重要色散元件, 由24块光栅和12块滤光片拼接而成. 光谱效率是无缝光谱组件的重要技术指标之一, 在研制过程中, 需要对无缝光谱组件的光谱效率进行检测. 由于无缝光谱组件外形包络较大, 无法使用商业光谱效率测量设备进行检测. 针对无缝光谱组件光谱效率测试的问题, 首先介绍了实验室搭建的无缝光谱组件光谱效率检测装置的基本结构和测量原理, 接着给出了无缝光谱组件鉴定件光谱效率测量的步骤和结果, 最后利用误差合成理论分析并计算了测量结果的精度. 测量和计算结果表明, 无缝光谱组件鉴定件平均光谱效率分别为GU波段51.9%、GV波段67.9%、GI波段71.6% (其中900--1000 nm波段为67.7%), 满足技术指标要求.

    Abstract:

    The slitless spectroscopy assembly of the Chinese Space Survey Telescope (CSST) will be installed in front of the main focal plane detector of the sky survey module to conduct wide-field, wide-band slitless spectral observations. As an important dispersion element of the sky survey module, the slitless spectroscopy assembly is composed of 24 gratings and 12 filters. Spectral efficiency is one of the important technical indicators of the slitless spectroscopy assembly, and it needs to be tested during the development process. Due to the large envelope of the slitless spectroscopy assembly, commercial spectral efficiency measurement equipment cannot be used for testing. This paper addresses the issue of spectral efficiency testing for the slitless spectroscopy assembly. Firstly, the basic structure and measurement principles of the slitless spectroscopy assembly spectral efficiency testing system built in the laboratory are introduced. Then, the steps and results of the spectral efficiency measurement for the initial sample of the slitless spectroscopy assembly are given. Finally, the accuracy of the measurement results is analyzed and calculated using error synthesis theory. The measurement and calculation results show that the average spectral efficiency of the initial sample for the slitless spectroscopy assembly is 51.9% in the GU band, 67.9% in the GV band, and 71.6% in the GI band (67.7% in the 900--1000 nm band), meeting the technical requirements.

    参考文献
    相似文献
    引证文献
引用本文

李顺,季杭馨,章华涛,张淑玲,胡中文.空间无缝光谱仪光谱效率测试及误差分析[J].天文学报,2025,66(2):21. LI Shun, JI Hang-xin, ZHANG Hua-tao, ZHANG Shu-ling, HU Zhong-wen. Spectral Efficiency Testing and Error Analysis of Space Slitless Spectrograph[J]. Acta Astronomica Sinica,2025,66(2):21.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2024-03-27
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2025-03-31
  • 出版日期: